Review



agena ma4 mass spectrometer  (agena bioscience)


Bioz Verified Symbol agena bioscience is a verified supplier
Bioz Manufacturer Symbol agena bioscience manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    agena bioscience agena ma4 mass spectrometer
    Agena Ma4 Mass Spectrometer, supplied by agena bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/agena+ma4+mass+spectrometer/agena+ma4+mass+spectrometer/pm31623701-69-99-106
    Average 90 stars, based on 1 article reviews
    agena ma4 mass spectrometer - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    Polymerase Chain Reaction:

    Article Title: NeoSeekTM STEC: A Multiplex Molecular Method for Detection and Identification of Select Shiga Toxin-Producing Escherichia coli in Beef.
    Article Snippet: H .: J AOAC I V . 103, No. 2, 2020 527 D ow nloaded from https://academ ic.oup.com /jaoac/article/103/2/523/5718378 by Birm ingham C ity U niversity user on 08 M ay 2024 (5) Place the plate(s) on a plate spinner and let the plate(s) turn for at least 10 min. (6) Centrifuge the plate(s) at 2500–4000 rpm for at least 2 min to get the resin packed into the bottom of the well. (f ) MS.—(1) Using a nanodispenser, dispense 10 nL of each PCR reaction product onto a 384-element SpectroCHIP bioarray. (2) Conduct MS data collection using the Agena MA4 mass spectrometer platform, according to Agena Bioscience standard recommendations (routine preventative maintenance and calibration conducted by Agena technical personnel). (g) Data analysis and reporting.—(1) Perform quality control (QC) checks and score and analyze the data. (2) Conduct final QC, adjust final profile calls as appropriate. (3) Report results as follows: (a) “STEC”—indicating target O group detected and stx and eae positive results. (b) A blank space or “Not Detected”—target O group was not detected. (c) “Non”—a target O group was detected but the profile obtained was not consistent with the presence of a potentially virulent STEC. (4) Upload results into laboratory information systems software, generate report, and report results to client.

    Mass Spectrometry:

    Article Title: NeoSeekTM STEC: A Multiplex Molecular Method for Detection and Identification of Select Shiga Toxin-Producing Escherichia coli in Beef.
    Article Snippet: H .: J AOAC I V . 103, No. 2, 2020 527 D ow nloaded from https://academ ic.oup.com /jaoac/article/103/2/523/5718378 by Birm ingham C ity U niversity user on 08 M ay 2024 (5) Place the plate(s) on a plate spinner and let the plate(s) turn for at least 10 min. (6) Centrifuge the plate(s) at 2500–4000 rpm for at least 2 min to get the resin packed into the bottom of the well. (f ) MS.—(1) Using a nanodispenser, dispense 10 nL of each PCR reaction product onto a 384-element SpectroCHIP bioarray. (2) Conduct MS data collection using the Agena MA4 mass spectrometer platform, according to Agena Bioscience standard recommendations (routine preventative maintenance and calibration conducted by Agena technical personnel). (g) Data analysis and reporting.—(1) Perform quality control (QC) checks and score and analyze the data. (2) Conduct final QC, adjust final profile calls as appropriate. (3) Report results as follows: (a) “STEC”—indicating target O group detected and stx and eae positive results. (b) A blank space or “Not Detected”—target O group was not detected. (c) “Non”—a target O group was detected but the profile obtained was not consistent with the presence of a potentially virulent STEC. (4) Upload results into laboratory information systems software, generate report, and report results to client.

    Control:

    Article Title: NeoSeekTM STEC: A Multiplex Molecular Method for Detection and Identification of Select Shiga Toxin-Producing Escherichia coli in Beef.
    Article Snippet: H .: J AOAC I V . 103, No. 2, 2020 527 D ow nloaded from https://academ ic.oup.com /jaoac/article/103/2/523/5718378 by Birm ingham C ity U niversity user on 08 M ay 2024 (5) Place the plate(s) on a plate spinner and let the plate(s) turn for at least 10 min. (6) Centrifuge the plate(s) at 2500–4000 rpm for at least 2 min to get the resin packed into the bottom of the well. (f ) MS.—(1) Using a nanodispenser, dispense 10 nL of each PCR reaction product onto a 384-element SpectroCHIP bioarray. (2) Conduct MS data collection using the Agena MA4 mass spectrometer platform, according to Agena Bioscience standard recommendations (routine preventative maintenance and calibration conducted by Agena technical personnel). (g) Data analysis and reporting.—(1) Perform quality control (QC) checks and score and analyze the data. (2) Conduct final QC, adjust final profile calls as appropriate. (3) Report results as follows: (a) “STEC”—indicating target O group detected and stx and eae positive results. (b) A blank space or “Not Detected”—target O group was not detected. (c) “Non”—a target O group was detected but the profile obtained was not consistent with the presence of a potentially virulent STEC. (4) Upload results into laboratory information systems software, generate report, and report results to client.

    Software:

    Article Title: NeoSeekTM STEC: A Multiplex Molecular Method for Detection and Identification of Select Shiga Toxin-Producing Escherichia coli in Beef.
    Article Snippet: H .: J AOAC I V . 103, No. 2, 2020 527 D ow nloaded from https://academ ic.oup.com /jaoac/article/103/2/523/5718378 by Birm ingham C ity U niversity user on 08 M ay 2024 (5) Place the plate(s) on a plate spinner and let the plate(s) turn for at least 10 min. (6) Centrifuge the plate(s) at 2500–4000 rpm for at least 2 min to get the resin packed into the bottom of the well. (f ) MS.—(1) Using a nanodispenser, dispense 10 nL of each PCR reaction product onto a 384-element SpectroCHIP bioarray. (2) Conduct MS data collection using the Agena MA4 mass spectrometer platform, according to Agena Bioscience standard recommendations (routine preventative maintenance and calibration conducted by Agena technical personnel). (g) Data analysis and reporting.—(1) Perform quality control (QC) checks and score and analyze the data. (2) Conduct final QC, adjust final profile calls as appropriate. (3) Report results as follows: (a) “STEC”—indicating target O group detected and stx and eae positive results. (b) A blank space or “Not Detected”—target O group was not detected. (c) “Non”—a target O group was detected but the profile obtained was not consistent with the presence of a potentially virulent STEC. (4) Upload results into laboratory information systems software, generate report, and report results to client.



    Similar Products

    90
    agena bioscience agena ma4 mass spectrometer
    Agena Ma4 Mass Spectrometer, supplied by agena bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/agena+ma4+mass+spectrometer/agena+ma4+mass+spectrometer/pm31623701-69-99-106
    Average 90 stars, based on 1 article reviews
    agena ma4 mass spectrometer - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results